  1. Home

Power Injector Installation for Cisco AP Arionet 1130AG

After connecting Cisco power injector to Arionet 1130AG access point apparently does not work until you run two commands:

no power inline negotiation prestandard source
power inline negotiation injector installed

It sems like CDP discovers the injector but it needs to have properly configured port (proper MAC address).